micro motion 2700 user manual

Get the Micro Motion 2700 User Manual for free. Your comprehensive guide to installation, operation, and troubleshooting.

The Micro Motion 2700 is a high-performance Coriolis transmitter designed for precise measurement of mass, volume, and density in industrial applications. This manual provides comprehensive guidance for installation, configuration, and operation. It ensures safe and effective use, covering key features like user-friendly display, multiple communication protocols, and customizable settings. Always follow safety precautions and procedures outlined in this guide.

Safety Precautions

Safety is paramount when working with the Micro Motion 2700 transmitter. Always follow the safety guidelines outlined in this manual to protect personnel and equipment. Read each safety message carefully before proceeding with any operation or maintenance task.

  • Intrinsic Safety: Ensure the transmitter is installed in an intrinsically safe environment if specified. Follow all applicable codes and regulations for hazardous locations.
  • Grounding: Proper grounding is essential to prevent electrical hazards. Verify that all components are grounded according to the manufacturer’s instructions.
  • Handling: Avoid exposing the transmitter to extreme temperatures, humidity, or physical stress. Use approved tools and equipment for installation and maintenance.
  • Compliance: Adhere to local and international safety standards. Ensure all personnel involved in installation or operation are trained and qualified.

Failure to comply with these precautions may result in equipment damage, personal injury, or legal consequences. Always refer to this manual for specific safety instructions before performing any task. By following these guidelines, you can ensure a safe and reliable operation of the Micro Motion 2700 transmitter.

Overview of the Micro Motion 2700 Transmitter

The Micro Motion 2700 is a state-of-the-art Coriolis transmitter designed for industrial applications requiring precise measurement of mass, volume, and density. Known for its versatility and accuracy, this device is widely used in various industries, including oil and gas, chemical processing, and food production. Its advanced technology ensures reliable performance in demanding environments.

Key features of the Micro Motion 2700 include a user-friendly interface, multiple communication protocols, and a range of configurable options. The transmitter supports analog and digital outputs, enabling seamless integration with existing control systems. Its robust design ensures durability, even in harsh industrial conditions. Additionally, the device offers advanced diagnostics and troubleshooting capabilities, enhancing operational efficiency.

The Micro Motion 2700 is compatible with both integral and remote sensor mounting options, providing flexibility for different installation requirements. It also supports various communication protocols, such as Modbus and Foundation Fieldbus, making it adaptable to diverse industrial settings. The transmitter’s ability to measure multiple process variables, including mass flow, density, and temperature, makes it a comprehensive solution for industrial measurement needs.

Emerson, the manufacturer, continuously updates the Micro Motion 2700 to meet evolving industry standards and customer demands. Regular firmware updates and a wide range of accessories ensure optimal performance and longevity. With its cutting-edge technology and user-centric design, the Micro Motion 2700 remains a trusted choice for precise and reliable industrial measurement.

Installation and Mounting

Proper installation and mounting of the Micro Motion 2700 transmitter are critical for accurate measurement and reliable operation. The transmitter can be mounted integrally, remotely, or on a pole, depending on the application. Ensure all safety precautions are followed, and the transmitter is aligned correctly with the sensor. Use genuine Micro Motion parts for mounting to maintain performance and warranty validity.

4.1 Integral Mounting

Integral mounting is the most common configuration for the Micro Motion 2700 transmitter, where the transmitter is directly attached to the sensor. This setup ensures optimal performance and simplifies installation. The transmitter can be rotated up to 360 degrees in 90-degree increments, allowing for flexible positioning and easy access to the display.

For integral mounting, align the transmitter with the sensor to ensure proper communication and measurement accuracy. Use the provided mounting hardware to secure the transmitter firmly to the sensor. Avoid over-tightening, as this may damage the sensor or transmitter.

Before mounting, ensure the area is clean and free from debris. Always follow the safety precautions outlined in the manual, such as disconnecting power before starting the installation. Proper grounding of the system is essential to prevent electrical noise and ensure reliable operation.

The integral mounting configuration minimizes cabling and reduces the risk of signal interference. It is ideal for applications where space is limited or where direct access to the transmitter is required. Always use genuine Micro Motion mounting hardware to maintain warranty validity and ensure system reliability.

After mounting, verify the alignment and connections to ensure proper functionality. Refer to the wiring and configuration sections for further instructions on connecting the transmitter to your process control system. Proper installation is critical for accurate measurements and long-term performance of the Micro Motion 2700 transmitter.

4.2 Remote Mounting

Remote mounting allows the Micro Motion 2700 transmitter to be installed separately from the sensor, providing flexibility in system design. This configuration is ideal for applications where the sensor is located in a hazardous or hard-to-reach area, or when the transmitter needs to be accessed frequently for configuration or monitoring.

To ensure proper operation, the transmitter must be connected to the sensor using a compatible 9-wire cable. The cable length should not exceed the maximum specified in the product manual to maintain signal integrity. Use only shielded cables to minimize electromagnetic interference, especially in noisy industrial environments.

Mount the transmitter in a safe and accessible location, such as on a wall or instrument pole. Secure the transmitter firmly to prevent vibration or movement, which could affect measurement accuracy. Always follow the torque specifications for mounting hardware to avoid damaging the transmitter or sensor.

For remote installations, ensure the transmitter is properly grounded to prevent electrical noise and ensure accurate measurements. The grounding terminal on the transmitter should be connected to a suitable earth point. Refer to the grounding and shielding section for detailed instructions.

After installing the transmitter, verify all connections and perform a system test to ensure proper communication with the sensor. Remote mounting offers advantages such as easier maintenance and reduced exposure to harsh environmental conditions. However, it requires careful planning and adherence to the manufacturer’s guidelines to ensure optimal performance.

Always use genuine Micro Motion accessories and follow the installation procedures outlined in this manual to maintain warranty validity and system reliability. Proper installation is essential for achieving accurate and reliable measurements with the Micro Motion 2700 transmitter.

4.3 Pole Mounting

Pole mounting is a convenient and versatile installation method for the Micro Motion 2700 transmitter, ideal for applications where wall or remote mounting is not feasible. This configuration allows the transmitter to be securely attached to an instrument pole, ensuring easy access for maintenance and configuration.

When selecting a pole, ensure it is sturdy enough to support the weight of the transmitter and any additional accessories. The pole should be constructed of durable material, such as aluminum or stainless steel, and should be properly anchored to prevent vibration or movement. Avoid using poles that are too thin or flexible, as this could affect the stability of the transmitter.

The transmitter can be mounted at any height, but it should be positioned to avoid exposure to direct sunlight, moisture, or other environmental factors that could impact performance. Use the mounting brackets provided by Micro Motion or equivalent hardware to ensure a secure fit. Tighten all bolts and screws according to the torque specifications provided in the manual to prevent loose connections over time.

For integral mounting configurations, the transmitter can be rotated up to 360 degrees in 90-degree increments, allowing for optimal positioning of the display and connectors. This feature is particularly useful for pole-mounted installations, where the orientation of the transmitter may need to be adjusted for ease of use.

After mounting the transmitter, perform a series of checks to ensure all connections are secure and the unit is functioning correctly. This includes verifying the integrity of the sensor wiring, checking for proper grounding, and testing the communication interfaces. Regular maintenance, such as cleaning the display and inspecting the mounting hardware, is essential to maintain the reliability and accuracy of the Micro Motion 2700 transmitter in pole-mounted installations.

Always refer to the Micro Motion 2700 user manual for specific guidelines and recommendations to ensure a successful installation. Proper pole mounting not only enhances the durability of the transmitter but also contributes to accurate and consistent measurement performance in industrial applications.

Wiring and Connections

Proper wiring and connections are critical for the Micro Motion 2700 transmitter’s accurate operation. Use shielded cables to minimize electromagnetic interference and ensure all connections are secure. Follow the recommended wiring layout to avoid signal degradation. Grounding is essential for noise reduction and safety. Always use the correct connector types and verify connections before startup. Refer to the manual for specific wiring guidelines.

5.1 Wiring Requirements

Proper wiring is essential for the optimal performance of the Micro Motion 2700 transmitter. Use shielded cables to minimize electromagnetic interference (EMI) and ensure reliable signal transmission. The transmitter supports various wiring configurations, including 4-wire and 9-wire setups, depending on the installation type. For remote mounting, a 9-wire cable is required to connect the sensor and transmitter.

Ensure all connections are secure and tightened to the specified torque to prevent signal degradation. Use the recommended connector types, as outlined in the manual, to maintain compatibility and ensure proper sealing. Grounding is critical for noise reduction and safety; connect the transmitter’s ground terminal to a suitable earth point. Avoid routing cables near high-voltage lines or sources of interference to maintain signal integrity.

For integral installations, the transmitter is mounted directly on the sensor, simplifying wiring. Remote installations require careful planning to ensure the cable length and routing meet specifications. Always verify wiring accuracy before powering up the system. Refer to the product manual for detailed diagrams and wiring recommendations specific to your application.

Use only approved cables and connectors to ensure compliance with safety standards. Proper wiring practices will help prevent errors, ensure accurate measurements, and prolong the lifespan of the transmitter. If unsure about any aspect of wiring, consult the manual or contact Micro Motion technical support for assistance.

5.2 Connector Types

The Micro Motion 2700 transmitter supports various connector types to accommodate different installation requirements. Common connectors include circular M12 connectors for sensor wiring and larger circular connectors for remote installations. These connectors are designed to ensure reliable signal transmission and durability in industrial environments.

Use only approved connectors to maintain compatibility and prevent signal degradation. For remote mounting, a 9-wire connector is typically required to connect the sensor and transmitter. Ensure all connectors are properly sealed to meet IP67 or higher ratings for protection against dust and water ingress.

Refer to the product manual for specific connector recommendations based on your application. Proper connector selection ensures accurate measurements, minimizes noise, and extends the lifespan of the transmitter. Always follow the manufacturer’s guidelines for connector installation and maintenance.

If uncertain about connector compatibility or wiring, consult the Micro Motion 2700 user manual or contact technical support for assistance. Properly matched connectors are essential for optimal performance and safety.

5.3 Grounding and Shielding

Proper grounding and shielding are critical for ensuring accurate measurements and preventing electromagnetic interference (EMI) in the Micro Motion 2700 transmitter. Grounding ensures that the transmitter and sensor are at the same electrical potential, minimizing noise and interference. Shielding protects the signal cables from external electrical disturbances.

Connect the transmitter’s grounding terminal to a suitable earth point, as specified in the installation manual. Use a low-resistance grounding wire to ensure effective grounding. For remote installations, ground the transmitter and sensor separately to avoid potential differences that could cause measurement errors.

Shielded cables are recommended for all sensor wiring to prevent EMI. The shield should be connected to the grounding terminal on both the transmitter and sensor ends. Ensure the shield is not damaged or pinched during installation, as this could compromise its effectiveness.

Follow the manufacturer’s guidelines for grounding and shielding to maintain the integrity of your measurements. Regularly inspect the grounding and shielding connections to ensure they remain secure and free from corrosion. Proper grounding and shielding are essential for reliable operation and compliance with safety standards.

Refer to the Micro Motion 2700 manual for detailed instructions on grounding and shielding specific to your application. Improper grounding or shielding can lead to inaccurate readings, equipment damage, or safety hazards.

Configuration

The Micro Motion 2700 configuration involves setting up communication protocols, adjusting measurement parameters, and utilizing software tools like LiveLink for precise operation. Proper configuration ensures accurate measurements, seamless integration with process control systems, and enhances efficiency. Follow the manual’s guidelines to optimize performance, ensure safety, and maintain reliability in industrial applications effectively.

6.1 Initial Setup and Startup

Before initiating the Micro Motion 2700 transmitter, ensure all safety precautions are followed. Begin by powering on the device and verifying the display interface is active. Use the navigation buttons to access the main menu and select the appropriate communication protocol for your system. Connect the transmitter to the sensor, ensuring all wiring is secure and meets the specified requirements.

Next, perform a self-test by navigating to the diagnostics menu. This step ensures all internal components are functioning correctly. If any issues are detected, refer to the troubleshooting section of the manual. Once the self-test is complete, configure the measurement parameters, such as volume, mass, or density, based on your application needs.

Calibrate the transmitter as required, following the on-screen instructions. Ensure the device is properly grounded to prevent interference. After configuration, test the system under operational conditions to verify accuracy. Regularly review the device’s status and update settings as necessary to maintain optimal performance. Always refer to the manual for detailed instructions and safety guidelines.

For remote installations, use the LiveLink software to configure and monitor the transmitter. This tool enables seamless integration with control systems and enhances operational efficiency. If issues arise during startup, consult the troubleshooting guide or contact technical support for assistance. Proper initialization ensures reliable and accurate measurements in your industrial application.

Leave a Reply